SOUND CONTROL ASSEMBLY : PGD-W-465-24
ASSEMBLY COMPONENTS
-
Acoustical
STC 56
NRC TLA-04-052
-
Fire
1 hr.
U309
-
Dimensions
Thickness: 6"
Approx. Weight: 11 lb/ft²
-
Bearing
Load Bearing
ASSEMBLY DETAILS
- 1-5/8’’ Type S screws spaced 16” o.c. (for fire 1-5/8” drywall screws spaced 12” o.c. in the perimeter and 8” o.c. in the field).
- Face layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.
- 1-5/8’’ Type S screws spaced 16” o.c. (for fire 1-7/8’’ Type S drywall screws spaced 7” o.c.).
- Base layer: 5/8” PABCO Flame Curb® type C gypsum panel applied vertically.
- 2 x 4 wood studs 24” o.c.
- 3-1/2”, R-13 glass fiber insulation friction fit into stud cavity.
- Base layer: 5/8” PABCO Frame Curb® type C gypsum panel applied vertically.
- 1-5/8’’ Type S screws spaced 16” o.c. (for fire 1-7/8’’ Type S drywall screws spaced 7” o.c.).
- Face layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.
- 1-5/8’’ Type S screws spaced 16” o.c. (for fire 1-5/8” drywall screws spaced 12” o.c. in the perimeter and 8” o.c. in the field).