SOUND CONTROL ASSEMBLY : PGD-W-465-24

ASSEMBLY COMPONENTS

  • Acoustical

    STC 56

    NRC TLA-04-052

  • Fire

    1 hr.

    U309

  • Dimensions

    Thickness: 6"

    Approx. Weight: 11 lb/ft²

  • Bearing

    Load Bearing

ASSEMBLY DETAILS

  • 1-5/8’’ Type S screws spaced 16” o.c. (for fire 1-5/8” drywall screws spaced 12” o.c. in the perimeter and 8” o.c. in the field).
  • Face layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.
  • 1-5/8’’ Type S screws spaced 16” o.c. (for fire 1-7/8’’ Type S drywall screws spaced 7” o.c.).
  • Base layer: 5/8” PABCO Flame Curb® type C gypsum panel applied vertically.
  • 2 x 4 wood studs 24” o.c.
  • 3-1/2”, R-13 glass fiber insulation friction fit into stud cavity. 
  • Base layer: 5/8” PABCO Frame Curb® type C gypsum panel applied vertically.
  • 1-5/8’’ Type S screws spaced 16” o.c. (for fire 1-7/8’’ Type S drywall screws spaced 7” o.c.).
  • Face layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.
  • 1-5/8’’ Type S screws spaced 16” o.c. (for fire 1-5/8” drywall screws spaced 12” o.c. in the perimeter and 8” o.c. in the field).