SOUND CONTROL ASSEMBLY : PGD-W-449-24
ASSEMBLY COMPONENTS
-
Acoustical
STC 57
NRC TLA-04-035
-
Fire
1 hr.
U309
-
Dimensions
Thickness: 5-3/8"
Approx. Weight: 9.3 lb/ft²
-
Bearing
Load Bearing
ASSEMBLY DETAILS
- 1-5/8” ’’ Type S drywall screws spaced 16” o.c. (for fire 2” screws spaced 12” o.c. in the perimeter and 8” o.c. in
- the field).
- Face layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.
- 2’’ Type S drywall screws spaced 16” o.c. (for fire 1-5/8” screws spaced 12” o.c. in the perimeter and 8” o.c. in the field).
- Base layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.
- 2 x 4 wood studs 24” o.c.
- 3-1/2”, R-13 glass fiber insulation friction fit into stud cavity.
- Opposite side One layer: 5/8” QuietRock® 530 or QuietRock® 530 RF type X gypsum panel applied vertically.
- 1-5/8” ’’ Type S drywall screws spaced 16” o.c. (for fire 2” screws spaced 12” o.c. in the perimeter and 8” o.c. in the field).