SOUND CONTROL ASSEMBLY : PGD-97-516-24
ASSEMBLY COMPONENTS
            - 
                            
Acoustical
STC 54
NOAL 19-0736
 - 
                            
Fire
1 hr.
U425
 - 
                            
Dimensions
Thickness: 5-3/8"
Approx. Weight: 7.1 lb/ft²
 - 
                            
Bearing
Load Bearing
 
ASSEMBLY DETAILS
- 1-1/4” Type S drywall screws spaced 8” o.c. at edges and 12” o.c. in the field. (for fire, minimum 1” screws spaced 12” o.c.)
 - One layer: 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.
 - 3-5/8” 97 mil steel studs, 24” o.c.
 - 3-1/2”, R-13 glass fiber insulation friction fit into stud cavity.
 - Resilient channel applied at right-angle, 24” o.c.
 - 1/2” Type S screws attaching resilient channel to stud at each intersection.
 - One layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.
 - 1” Type S drywall screws spaced 12” o.c.