SOUND CONTROL ASSEMBLY : PGD-546-493-16

ASSEMBLY COMPONENTS

  • Acoustical

    STC 48

    NOAL 21-0356

  • Fire

    1 hr.

    U425

    WP-1359

  • Dimensions

    Thickness: 7-1/4"

    Approx. Weight: 7.6 lb/ft²

  • Bearing

    Load Bearing

ASSEMBLY DETAILS

  • 1” Type S drywall screws 8” o.c. at edges and 12 “ o.c. in the field. (For fire, minimum 1” screws spaced 12”o.c.)
  • One layer: 5/8” QuietRock® ES or QuietRock® ES MR Type X gypsum panel applied vertically.
  • 6” 54 mil steel studs, 16” o.c.
  • 6”, R-19 glass fiber insulation friction fit into stud cavity.
  • One layer: 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.
  • 1” Type S drywall screws 8” o.c. at edges and 12 “ o.c. in the field. (For fire, minimum 1” screws spaced 12”o.c.)