SOUND CONTROL ASSEMBLY : PGD-546-407-16
ASSEMBLY COMPONENTS
-
Acoustical
STC 60
NOAL 21-0358
-
Fire
1 hr.
U425
-
Dimensions
Thickness: 8-3/8"
Approx. Weight: 9.2 lb/ft²
-
Bearing
Load Bearing
ASSEMBLY DETAILS
- 1” Type S drywall screws spaced 8” o.c. at edges and 12” o.c. in the field. (For fire, minimum 1” screws spaced 12” o.c.)
- One layer: 5/8” QuietRock® ES or QuietRock® ES MR Type X gypsum panel applied vertically.
- 6” 54 mil steel studs, 16” o.c.
- 6-1/4”, R-19 glass fiber insulation friction fit into stud cavity.
- Resilient channel applied at right-angle, 24” o.c.
- 1/2” Type S screws attaching resilient channel to stud at each intersection.
- Base layer: type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.
- 1” Type S drywall screws spaced 12” o.c.
- Face layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.
- 1-5/8” Type S drywall screws spaced 12” o.c.