SOUND CONTROL ASSEMBLY : PGD-336-432-16
ASSEMBLY COMPONENTS
-
Acoustical
STC 58
NOAL 20-1235
-
Fire
1 hr.
U425
-
Dimensions
Thickness: 8-5/8"
Approx. Weight: 11.7 lb/ft²
-
Bearing
Load Bearing
ASSEMBLY DETAILS
- 2” Type S-12 drywall screws spaced 8” o.c. at edges and 12” o.c. in the field.
- One layer: 1-3/8” QuietRock® 545 gypsum panel applied vertically.
- 6” 33 mil steel studs, 16” o.c.
- 6-1/2”, R-19 glass fiber insulation friction fit into stud cavity.
- Base layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.
- 1-1/4” Type S-12 drywall screws spaced 8” o.c. at edges and 12” o.c. in the field. (for fire, minimum 1” Type S-12 drywall screws spaced 12” o.c.)
- Face layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.
- 1-5/8” Type S-12 drywall screws spaced 8” o.c. at edges and 12” o.c. in the field. (for fire, screws spaced 12” o.c.)