SOUND CONTROL ASSEMBLY : PGD-33-497-24

ASSEMBLY COMPONENTS

  • Acoustical

    STC 58

    NOAL 22-0917

  • Fire

    2 hrs.

    U425

  • Dimensions

    Thickness: 6-1/8

    Approx. Weight: 10.6 lb/ft²

  • Bearing

    Limited Load Bearing

ASSEMBLY DETAILS

  • 1-5/8” Type S-12 screws spaced 12” o.c. 
  • Face layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically. 
  • 1-1/4” Type S-12 screws spaced 12” o.c. (for fire, minimum 1” S-12 screws).
  • Base layer: 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.
  • 3-5/8” 33 mil steel studs, 24” o.c.
  • 3-1/2”, R-13 glass fiber insulation friction fit into stud cavity. 
  • Base layer: 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.
  • 1-1/4” Type S-12 screws spaced 12” o.c. (for fire, minimum 1” S-12 screws).
  • Face layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically. 
  • 1-5/8” Type S screws spaced 12” o.c.