SOUND CONTROL ASSEMBLY : PGD-19-394-24

ASSEMBLY COMPONENTS

  • Acoustical

    STC 60

    NOAL 17-0530

  • Fire

    1 hr.

    U465

    WP-0951

  • Dimensions

    Thickness: 6"

    Approx. Weight: 7.8 lb/ft²

  • Bearing

    Non-Load Bearing

ASSEMBLY DETAILS

  • 1-5/8” Type S screws spaced 8” o.c. at edges and 12” o.c. in the field. 
  • Face layer: 5/8” type X (FLAME CURB®, PABCO® Glass Interior, PABCO® Glass Sheathing) gypsum panel applied vertically.
  • 1” Type S screws spaced 8” o.c. at edges and 12” o.c. in 
  • the field. 
  • Base layer: 5/8” type X (FLAME CURB®, PABCO® Glass Interior, PABCO® Glass Sheathing) gypsum panel applied vertically.
  • 3-5/8” 19 mil steel studs, 24” o.c.
  • 3-1/2”, R-13 glass fiber insulation friction fit into stud cavity. 
  • Resilient channel applied at right-angle, 24” o.c. 
  • 1/2” Type S screws attaching resilient channel to stud at each intersection.
  • One layer: 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.
  • 1” Type S screws spaced 12” o.c.