SOUND CONTROL ASSEMBLY : PGD-15S-286-16

ASSEMBLY COMPONENTS

  • Acoustical

    STC 65

    NOAL 17-0914

  • Fire

    1 hr.

    V464, Config B

  • Dimensions

    Thickness: 9-1/8"

    Approx. Weight: 8.1 lb/ft²

  • Bearing

    Non-Load Bearing

ASSEMBLY DETAILS

  • 1” Type S drywall screws spaced 8” o.c. at edges and 12” o.c. in the field. 
  • One layer: 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.
  • Staggered-double row 3-5/8” 15 mil steel studs, 16” o.c.
  • 6-1/4” , R-19 glass fiber insulation friction fit into stud cavity.
  • Base layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically. 
  • 1” Type S drywall screws spaced 8” o.c. at edges and 12” o.c. in the field. 
  • Face layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically. 
  • 1-1/4” Type S drywall screws spaced 8” o.c. at edges and 12” o.c. in the field. (For fire, minimum 1” screws spaced 12” o.c.)