SOUND CONTROL ASSEMBLY : PGD-15S-286-16
ASSEMBLY COMPONENTS
-
Acoustical
STC 65
NOAL 17-0914
-
Fire
1 hr.
V464, Config B
-
Dimensions
Thickness: 9-1/8"
Approx. Weight: 8.1 lb/ft²
-
Bearing
Non-Load Bearing
ASSEMBLY DETAILS
- 1” Type S drywall screws spaced 8” o.c. at edges and 12” o.c. in the field.
- One layer: 5/8” QuietRock® ES or QuietRock® ES MR type X gypsum panel applied vertically.
- Staggered-double row 3-5/8” 15 mil steel studs, 16” o.c.
- 6-1/4” , R-19 glass fiber insulation friction fit into stud cavity.
- Base layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.
- 1” Type S drywall screws spaced 8” o.c. at edges and 12” o.c. in the field.
- Face layer: 5/8” type X (FLAME CURB®, MOLD CURB® Plus, ABUSE CURB®, PABCO® Impact Resistant, PABCO® Glass Interior, PABCO® Glass Sheathing or PABCO® Gypsum Sheathing) gypsum panel applied vertically.
- 1-1/4” Type S drywall screws spaced 8” o.c. at edges and 12” o.c. in the field. (For fire, minimum 1” screws spaced 12” o.c.)